North Carolina Waterproofing

Basement Waterproofing - Regional Waterproofing, Inc. - North Carolina

Ultra-Shield GMX

Exterior Wall Waterproofing
Ultra-Shield  is a cost-effective, polymer modified sealer with excellent elastomeric  properties. It is designed and recommended for use as the membrane  component in an exterior wall waterproofing system. Ultra-Shield forms  a tough, durable membrane which bridges shrinkage cracks, resists the  attack of fungus, mold and bacteria and maintains its superior  performance properties when exposed to chemicals found in the soil.

Maximizes Living Space
The Ultra-Shield waterproofing system ensures a less humid, more comfortable basement. The insulation layer "equalizes" foundation wall and basement air temperatures thereby reducing condensation. In  addition, it minimizes potential wall damage due to uncontrolled  freeze/thaw cycles. The basement remains leak-free, less humid and more  liveable.

Economical, "Quick Dry" Application
Ultra-Shield  can be spray-applied to poured walls immediately after the forms are  removed, even at ambient temperatures as low as 20 F. On block  surfaces, Ultra-Shield can be applied as soon as the mortar is dry. As  a result, construction delays, application time and labor costs are  minimized.

The Custom-Tailored Waterproofing System
Ultra-Shield  is compatible with a wide range of drainage, protection and insulation  boards. The applicator can engineer a waterproofing system "tailored"  to your budget, local construction practices and your individual job  requirements.

Basement Waterproofing - Regional Waterproofing, Inc. - North CarolinaDurable, Long-Term Membrane Protection
Ultra-Shield  forms a tough, flexible seal which protects below grade wall surfaces  far longer than conventional damp proofing products. It resists mold  growth, bacteria and chemical attack, and Ultra-Shield maintains its  flexibility and integrity after years of extended exposure to water and  soil. A limited 10 year labor and material warranty is available.

Reduces Home Energy Use
Typically, a considerable portion of the home's energy bill is required to heat uninsulated basement walls.  The addition of insulation board to the Ultra-Shield waterproofing  system minimizes heat loss through the basement wall and reduces home  energy use.

GMX Ultra-Shield Installation

GMX installation procedures must be carefully observed to ensure  that the application qualifies for the warranty. These procedures are  summarized below:

  • The foundation walls and footings must be dry and of sufficient  strength and design to ensure structural integrity. Do not apply  Ultra-Shield over standing water. Allow the concrete wall or mortar  joints to cure a minimum 16 hours before applying Ultra-Shield.
  • Remove dirt, debris, excess mortar, etc. from the footings and  foundation walls. Repair all honeycombed concrete or cracks in the  walls and footings with non-shrinking grout. In some areas, concrete  block surfaces must be parged to produce a suitable surface for the  application of Ultra-Shield. Consult your local building official.
  • Repair/fill voids around tie holes, recessed ties, and other small voids with a suitable, solvent-based asphalt mastic.
  • After the wall and footing surfaces have been properly  prepared, spray apply Ultra-Shield over the exterior foundation walls  and footings. Apply Ultra-Shield at a rate of 20 to 25 sq. ft. per  gallon. On unparged block surface, more material and/or additional  application passes may be required. Do not apply Ultra-Shield at  temperatures below 20 F. To ensure a smooth, successful spray  application, heat the material to 120 to 160 F immediately prior to  application.
  • Upon completion of spray application, check for any surfaces  which were not properly covered. Apply a touch up coat to these areas.  In areas where an excessive amount of material was applied, brush out  the excess to a thickness no greater than 1/8 inch.
  • Install the insulation, drainage or protection board over the  Ultra-Shield membrane within one to three hours after membrane  application. Press the material firmly into place.
  • The installation of drain tile and the backfilling operation  may proceed immediately after the installation of the insulation board.  Do not leave the sealer unprotected for more than 15 days. Long term  exposure to sunlight may impair the sealer's performance properties.
  • Drain tile must be installed per the manufacturer's  recommendations to ensure proper removal of water from the foundation  walls and footings.
  • Backfill must be graded to direct surface water away from the exterior foundation walls.

Basement Waterproofing - Regional Waterproofing, Inc. - North Carolina

Ultra-Shield should be applied to smooth, properly prepared concrete wall surfaces. No priming is required.

Basement Waterproofing - Regional Waterproofing, Inc. - North Carolina

Ultra-Shield is designed for quick, economical spray applications.

Basement Waterproofing - Regional Waterproofing, Inc. - North Carolina

Concrete wall surface after treatment with Ultra-Shield membrane.

Basement Waterproofing - Regional Waterproofing, Inc. - North Carolina

Ultra-Shield  is compatible with a wide range of insulation, drainage or protection  boards. The applicator can "tailor" a waterproofing system to your job  or budget requirements.




(C) Copyright 2009 - All Rights Reserved
Serving Raleigh/Durham/Chapel Hill, Fayetteville, Rocky Mount, High Point, Wilmington, Apex/Cary, NC